Assessment of the electrical energy consumption in the academic building iv at cspc main campus / Danrell Glenn S. Donato [and 4 others].

By: Contributor(s): Material type: TextTextDescription: 166 leavesContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Dissertation note: Undergraduate Theses (BSEE) - Electrical Engineering Camarines Sur Polytechnic Colleges, 2024 Abstract: This study evaluated the electrical energy consumption and voltage unbalance in Academic Building IV at CSPC's College of Computer Studies. Using a quantitative approach, real-time data were collected over one week with a clamp meter to measure current, voltage, and power factor. The results revealed a weekly consumption of 3740.9 kWh with peak usage at 11:00 am on weekdays and significantly lower usage during weekends. Air conditioning units (Meters 5, 8, and 11) were identified as the primary contributors to energy consumption, while lighting and convenience outlets consumed minimal power. Load analysis showed some panels nearing capacity limits, necessitating careful load distribution. Voltage unbalance was also observed, primarily due to uneven single-phase load distribution. Recommendations include proper sizing of air conditioning units, implementation of advanced metering systems, energy conservation measures, and strategic load management to enhance system efficiency and prevent overloading.
Tags from this library: No tags from this library for this title. Log in to add tags.
Holdings
Item type Current library Shelving location Call number Copy number Status Date due Barcode
Unpublished Materials Unpublished Materials Main Library Undergraduate Thesis Section UTH BSEE D715a 2024 (Browse shelf(Opens below)) 1 - 1 Not for loan 006556UM

Undergraduate Theses (BSEE) - Electrical Engineering Camarines Sur Polytechnic Colleges, 2024

Includes bibliographic references.

This study evaluated the electrical energy consumption and voltage unbalance in Academic Building IV at CSPC's College of Computer Studies. Using a quantitative approach, real-time data were collected over one week with a clamp meter to measure current, voltage, and power factor. The results revealed a weekly consumption of 3740.9 kWh with peak usage at 11:00 am on weekdays and significantly lower usage during weekends. Air conditioning units (Meters 5, 8, and 11) were identified as the primary contributors to energy consumption, while lighting and convenience outlets consumed minimal power. Load analysis showed some panels nearing capacity limits, necessitating careful load distribution. Voltage unbalance was also observed, primarily due to uneven single-phase load distribution. Recommendations include proper sizing of air conditioning units, implementation of advanced metering systems, energy conservation measures, and strategic load management to enhance system efficiency and prevent overloading.