Assessment of compliance of the electrical system in one of the national high school in Bula based on the Philippine electrical code / Joemel C. Balatan, [and 5 others].
Material type:
TextDescription: 98 leavesContent type: - text
- unmediated
- volume
| Item type | Current library | Shelving location | Call number | Copy number | Status | Date due | Barcode | |
|---|---|---|---|---|---|---|---|---|
Unpublished Materials
|
Main Library | Undergraduate Thesis Section | UTH BSEE B171a 2024 (Browse shelf(Opens below)) | 1-1 | Not for loan | 006953UM |
Browsing Main Library shelves, Shelving location: Undergraduate Thesis Section Close shelf browser (Hides shelf browser)
| No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
| UTH BSEE B144m 2017 Microcontroller-based egg incubator/ | UTH BSEE B1461s 2022 Smart home with time-delay control / | UTH BSEE B146e 2024 Enhanced aeroponic control and camera based monitoring system / | UTH BSEE B171a 2024 Assessment of compliance of the electrical system in one of the national high school in Bula based on the Philippine electrical code / | UTH BSEE B182e 2022 Electrical safety practice of electricians in Iriga City / | UTH BSEE B193a 2012 Automatic poultry feeder : an innovation / | UTH BSEE B193u 2021 Underground secondary distribution system of Camarines Sur Polytechnic Colleges |
Undergraduate Theses (BSEE) - Electrical Engineering. Camarines Sur Polytechnic Colleges, 2024.
Includes bibliographical references.
This study evaluated the compliance of the electrical system at Balaogan National High School, Bula, Camarines Sur, with the 2017 Philippine Electrical Code (PEC). The research focused on the assessment of electrical loads, wiring systems, and protective devices across various buildings within the school, recognizing the critical role of electrical infrastructure in ensuring safety and supporting educational activities. A descriptive quantitative method was employed, utilizing site inspections, load computations, and informal interviews for data collection. Results showed that while most buildings complied with permissible load limits, several deficiencies were found in wiring sizes and protective devices. Undersized duplex wires and the use of outdated fuses were common, and some rooms lacked appropriate circuit breakers, presenting potential safety hazards. The study recommends replacing fuses with properly rated circuit breakers, correcting wire sizes, and installing separate circuits for lighting and power outlets. These measures are vital to ensure PEC compliance and enhance the overall safety, efficiency, and reliability of the school's electrical system.
There are no comments on this title.