Design of an automatic fire sprinkler system in the green building at Camarines Sur Polytechnic Colleges, Nabua, Camarines Sur /
Beloro, Grace Valery S.
Design of an automatic fire sprinkler system in the green building at Camarines Sur Polytechnic Colleges, Nabua, Camarines Sur / Grace Valery S. Beloro, [and 5 others]. - 134 leaves.
Undergraduate Thesis (BSME) - Mechanical Engineering.
Includes bibliographic references.
This study focuses on the design, installation, and operation of an Automatic Fire Sprinkler System (AFSS) for a green educational building at Central State Polytechnic College (CSPC) in Nabua, Camarines Sur. Its objective is to implement a system that ensures rapid fire suppression in line with the National Fire Protection Association (NFPA) standards and the Fire Code of the Philippines. A wet pipe system was selected based on the building's Ordinary Hazard Group 2 classification and tropical climate. The design, compliant with NFPA 13 and NFPA 25, delivers 500 gallons per minute through a 30,000-gallon tank with a 60-minute capacity. The system comprises 186 sprinkler heads and incorporates alarms, including flow switches and smoke detectors. The installation was conducted by NFPA guidelines, resulting in a total project cost of P2,063,641.33. Regular maintenance, including NFPA 1911 pump testing and inspection for corrosion or blockage, ensures continued functionality and fire protection.
Design of an automatic fire sprinkler system in the green building at Camarines Sur Polytechnic Colleges, Nabua, Camarines Sur / Grace Valery S. Beloro, [and 5 others]. - 134 leaves.
Undergraduate Thesis (BSME) - Mechanical Engineering.
Includes bibliographic references.
This study focuses on the design, installation, and operation of an Automatic Fire Sprinkler System (AFSS) for a green educational building at Central State Polytechnic College (CSPC) in Nabua, Camarines Sur. Its objective is to implement a system that ensures rapid fire suppression in line with the National Fire Protection Association (NFPA) standards and the Fire Code of the Philippines. A wet pipe system was selected based on the building's Ordinary Hazard Group 2 classification and tropical climate. The design, compliant with NFPA 13 and NFPA 25, delivers 500 gallons per minute through a 30,000-gallon tank with a 60-minute capacity. The system comprises 186 sprinkler heads and incorporates alarms, including flow switches and smoke detectors. The installation was conducted by NFPA guidelines, resulting in a total project cost of P2,063,641.33. Regular maintenance, including NFPA 1911 pump testing and inspection for corrosion or blockage, ensures continued functionality and fire protection.